Farming Simulator Mods


Troubleshooting a well pressure switch


FS 19 Maps


troubleshooting a well pressure switch After removing the cover of the pressure switch, you will be able to find the factory preset settings inside the cover or on the box of the pump. The job of the pressure switch is to detect the level of pressure inside the well tank and turn the well pump on and off accordingly. Load switches are applied to interact with a variation in pressure, and it will open or close an electrical switch when a preset pressure is attained. Solving the Problem. When the pressure is too low, the compressor risks damage due to running with low oil. When water leaves the pressure tank and the pressure level drops below a certain point, the pressure switch turns on, allowing the pump to pull more water into Oct 22, 2021 · The pressure in the system increases and when it is high enough the second pressure switch switches the pump off. In a pressure switch, control box 2 hot wire enters from 2 opposite sides-one from the well pump and the other Aug 20, 2020 · Well, there’s a thing called the pressure switch. You should check your well for any signs of ants around that area. Since the switch shuts off the pump when the pressure drops below about 20 psi or so, in most cases it will turn off the pump’s motor if the well Nov 27, 2020 · Check the Pressure Switch If flipping the breaker switch does not work, it is time to check the pressure switch. Oct 15, 2021 · How to Troubleshoot Residential Well Problems Written by Laurie Brenner, Updated J Modern well systems have more components that can fail than their older counterparts. There are adjustments for the cut in and out pressures. It shows the components of the circuit as simplified shapes, and the capacity and signal friends in the middle of the devices. Well Pump. Well Pump Pressure Switch Adjustment. Jan 10, 2018 · The drop in pressure may occur if you attempt to use a greater volume of water than either the well or well pump can produce. I suffered from low water pressure for a couple of years, then started messing with this stuff in the basement. Common Well Problems Even with regular maintenance, wells can suffer from the occasional problem, most of which are more of a nuisance than an actual health risk. A bellow or diaphragm is applied to interact with the alteration of pressure, and is utilized to enlarge or become Jul 06, 2020 · 1. Keep reading to learn how a pressure switch works on a well pump and the simple troubleshooting steps to identify the problem. Apr 14, 2020 · Adjust a Square D well pressure switch by turning it clockwise to raise the pressure and counter-clockwise to decrease the pressure. Dec. I have a cheap water pump that has been working faithfully for the last 4 years but this year, when I turned it on for the first time, I go… Apr 10, 2020 · The pressure switch to a well pump may shut down a well or cause the water not to flow, especially if both the switch and a pressure tank are affixed to the system. If it has, reset it. Use a new pressure gauge on a hose bib to see what your actual pressure is. Record the pressure switch setting if available. I checked the wiring under the well cap (R-R, B-B, Y-Y) and called the guy who installed the pump to find out what he did with the ground. This controls the automatic activation of the pump. The pressure switch circuit is open or the induced draft blower is going. You will notice trails and even ant hills if there are ants present. If the water pressure is floating around 40 psi or below, increase it by adjusting the pressure switch (this is located on the pipe connecting the well and pressure tank) Turn on the circuit and test out the Turn power to the pump off. The main cause for sump pumps to not operate properly is the switch. Adjust the air pressure in the tank with your compressor (or bike pump) to 2 PSI less than the desired pump turn-on point. Both parts can cause an over-circulation of water, which, in turn, shuts down a system. Nov 21, 2012 · I am only familiar with a well pump on the surface with a sandpoint well. Oct 30, 2013 · A well system will have at a minimum a well pump (in the photo above the well pump is submersed in the well), supply pipes, a pressure switch to tell the pump when to turn on and off, power to operate the pump, a power shut off (not shown) and a water shut off valve. Sep 24, 2017 · During the night, water pressure drops to 0 psi. Troubleshooting a 4-20mA Transducer Removed from a Pipeline This process is a little more complicated than the previous, because the only instrument that directly measures current is an analog meter. 3. If it has tripped, you will Check the well tank pressure gauge to see if it is at least 40 Dec 26, 2018 · If you’re having issues with your well pump not starting, not starting consistently, or starting too often, the first thing to check is your pressure switch. A pressure switch is the mechanism that will turn on and turn off the well pump based on the This is an affordable solution that can also help address water pressure issues for owners of condominiums on the upper floors of a building, or for homes where the well is located a great distance from the home. Homeowners may also be able to fix low pressure problems by adjusting their pressure tank. Steps to adjust the pressure switch on a pump. Notice that there are electrical wires from the tubing that connects to the pump and directly to the circuit breaker box. If gauge pressure drops, the check or foot valve is faulty. Oct 01, 2018 · Mechanical failure – Problems with the well pump, regulator switch or other components can result in low pressure. When the pressure reaches 60psi Mar 19, 2021 · The pressure switch is typically pre‐set correctly for the application. Water Pump Pressure Switch Troubleshooting 2009-07-31Water Pump Pressure Switch Troubleshooting Every well system needs a pump to retrieve water from under the ground. John’s Well Drilling provides a range of diagnostic, repair, testing, well maintenance services for private well owners. On most well systems I ignore the pressure gauge at the tank. Sep 24, 2013 · A pressure switch with a brass pressure sensing port and elastomeric diaphragm (such as Buna N or Viton) may work well for some applications but will not last as long as a pressure switch with the chemical resistance of a weld-sealed stainless steel diaphragm and sensing port in many industrial applications. These tanks have gauges which tell the Check tank sizing, (Replace tank). Current will pass through the burner pressure switch to the All Remco pumps pressure switches are factory preset but can be adjusted using a 1/16 th Allen wrench. This has a pressure switch that turns the pump on at a certain pressure and off at a higher pressure. If the switch is reading the pressure as being lower than the actual pressure, fixing the discrepancy should solve your pressure problems. Still nothing. Remove the cover of the switch and access the mechanism of the pressure switch. NOTICE: The switch should never be adjusted to cut-on below 20 PSI, or cut-off above 60 PSI. There are two numbers on the switch that denote at what point the switch cuts in and cuts off. To examine the switch itself, turn the electricity off, and Feb 04, 2019 · Pressure switches are used in a variety of applications. For example, if the preset settings say 30 psi cut in and 2. If I was standing there like you listening to it go thump thump. Regular Testing Lowers Risk Well owners can mitigate their risk of any of these problems with regular well water testing. To avoid the need for that pump to run whenever water is needed, the system usually includes a tank that stores pressurized water. Pressure switches with manual reset lock off after switching. The unit could be starved for power, have a weak ground, have low voltage, a poor connection or burnt contacts on starter or pressure switch etc…Amp probe will most likely show over-amping. He said that he grounded the pump to the well casing. Then check the well's double-pole circuit breaker to see that it hasn't tripped. Feb 23, 2021 · The pressure control switch sends the signal to the tank that it needs to turn on or off. Inspect the Pressure Tank. 24/7 emergency pump repair services. Recently, when I am taking a shower, I lose all water pressure for about 2 minutes. This usually indicates that your water tank is saturated. If a pressure transducer fails during use, measure the raw voltage or amperage emitted by the transducer at no pressure, and again at the pressure transducer’s full capacity. Step 2. Continue reading below Our Video of the Day. Dec 31, 2012 · 1/1/2013 at 6:14:55 AM. Check the water pump breaker in your electrical box to make sure the breaker hasn’t tripped. Contact 77 Water Well at 281-456-4556 or email us at service@77waterwell. Pitless adapter installations and repairs. • Dead-head pressure: This is the pressure the pump Apr 04, 2018 · Inspect your well: In some cases, water pressure issues may be attributed to the setup of the well itself, in which there is a low flow situation in which there is not enough water available to be drawn. A pressure switch is the mechanism that will turn on and turn off the well pump based on the Dec 18, 2018 · The pressure switch is a part of the well pump system that sends a signal to the pump to start or stop pumping based on the pressure that’s built up in the water system. Often, the appropriate fix involves work on one of the system components, such as: The pressure switch will be seen in the basement of your house, garage or pool area. With the plumbing pliers, in counterclockwise direction turn top screw cap. We now have another problem. Troubleshooting Guide - Check the bladder pressure tank air charge Disconnect electrical power to the pump. The line should be coming from the deep well to the pressure tank. Check the switch setting to make sure it hasn’t drifted or been reset to a level higher than the pump’s stated capacity. It's used to turn the pump on when the pressure gets low ( around 40 PSI) and turn it off when it gets high ( around 60 PSI). Step 3: Step 1. It is a small box attached to the water line with electrical wires running to it from your water pump. There are just two settings to these pressure switches: cut-in and cut-off. In ½ turn increments, adjust your pressure switch set screw clockwise until cycling stops. If the gauge reads 0 – 20 psi then check the well or water pump breaker in the electrical box to see if the switch was tripped. Nov 04, 2007 · So, I replaced the wires from the pressure switch to the control box, in case there was a break somewhere in that line. Mar 19, 2021 · The pressure switch is typically pre‐set correctly for the application. To do so, turn your electrical box off. Faulty check or foot valve. These are just somethings to be aware of. I never set a pressure switch above 60 psi on a well system. The location of the switch is at the plumbing system. A pressure switch is the mechanism that will turn on and turn off the well pump based on the Mar 16, 2021 · Step 1. Close the switch, if when you do this the pump does not turn on the problem is the pump. Get bathroom remodel shower ideas from our friends at Mr. If you are experiencing the following issues, it’s possible your pressure switch has failed or malfunctioned: There is no water and the pump doesn’t turn on at all The pump keeps cycling The pump is working but the water pressure is weak Nov 12, 2018 · Problems with the pressure switch are a common reason for these issues. 5. Check the pressure switch hose for blockages and ensure it is connected properly. 715-247-4873. Call us at. To ensure the power is off, be sure to check it with a volt-meter first. Review any system discrepancies or perceived problems in operation. Replacing the pressure switch is cheap and takes only about The pressure switch on this line would not shut off. Check the air pressure in the pressure tank with a tire gauge at the air valve located on the tank. This switch maintains the water pressure by turning on and off the system as needed. Dec 01, 2008 · Troubleshooting Residential Submersible Pump Systems. (Close valve between tank and house. Step 2: You will need to run power from the breaker box to the pressure switch. The burner pressure switch is factory preset to ensure that a minimum of 2/3 the normal rate of combustion air is passed into the combustion chamber. Throttle pump output or reset pump to lower level. 4 LED flashes. A breaker that keeps tripping likely means a problem with the well pump, and you'll need to call a pro for that. The switch is there to prevent the furnace from running unless the correct venting air pressure is present. Pressure switches with an 0. How Does A Well Pump Pressure Switch Fail? The pressure switch will be having springs to set the pressure and also has the electric wiring to give the signal to the pump to switch on and off. Pressure tanks are usually pre-charged at 30 PSI. 1, 2008. The new 40/60 switch will NOT work. Spread The Knowledge! Han. Without the switch, the pump will not turn on. First thing to do is to check and see what the pressure gauge is reading on the water (well) tank. DO NOT EXCEED 3 FULL TURNS. Clean contacts, replace switch, or adjust setting. Put the multimeter probes on wiring terminals, and if there is continuity during the test, the Jun 28, 2020 · I just installed a new pressure switch on my out side water well pump. The pressure switch on this installation was a 30/50 PSI switch meaning it should cut in when the pressure reaches 30 PSI and should cut off when the pressure reaches 50 PSI. Our technicians come with the necessary knowledge and expertise to efficiently detect any well pump issues , including that of the pressure switch. Look at the amp rating on the motor plate and put an amp probe on the motor if and when it starts bogging down. Your furnace’s primary limit circuit is open, probably from loose wiring. John’s Well Drilling has employees on call nights and weekends and we stock a wide range of parts so you’re issue can be fixed as soon as possible. Any air flow restriction resulting in less than 2/3 normal rate will cause the pressure switch to open and shut down the entire system. The switch could ‘activate’ either on a pressure rise or a pressure fall. Malfunctions can happen due to a blown circuit, power outage or a broken component. Aug 24, 2021 · A furnace pressure switch is a safety device located near the draft inducer motor of a gas forced-air furnace. We replaced the pressure switch and hose also and now all is well. are available. New pressure switch for pump installed th … read more 6. There are basically three types of switches; vertical, diaphragm, and tethered. Seriously! Smacking the tube will jar the electrical contacts. Problems with low pressure switch (30-50 psi) Author: antowas (VA) Hoping someone can help me with this one, because I am stumped. If your well is running dry, use the following troubleshooting guide to determine if you need well pump repair in Columbia, TN. When the switch acts up (and they all do eventually), you’ll see all kinds of strange behavior (pump won’t turn on, turns on erratically or won’t shut off). In order to troubleshoot issues with your pressure switch, it’s helpful to understand how a well pump pressure switch works. The test should be done when the pressure is not applied, the power is OFF, and when the switch is disconnected. Why is it that residential deep well submersible pump system malfunctions are notoriously hard to diagnose? For one, a pump/motor assembly suspended 10 feet from the bottom of a 300-foot well brings new meaning to the word The symptoms also have a troublesome way of overlapping Pressure switch C6097A switches in the event of de - creasing pressure, C6097B switches in the event of increasing pressure. If the breaker is not tripped Nov 02, 2021 · Touch the pressure switch terminals with each tester probe. Your well pump gets its marching orders from the switch mounted on the pressure tank. Always remember and be sure that you have turned off the breaker or disconnect the power going to the switch or to the pump. System Pressure The pressures in a well pump system must keep a set relationship. 6. A pressure switch is the mechanism that will turn on and turn off the well pump based on the Some ant bait near the pressure switch may be used to help prevent this from happening. If the submersible well pump won’t start, there could be one of three things wrong. Jul 05, 2021 · A pressure switch is responsible for turning the well pump on and off as the water pressure inside the pressure tank changes. Whether it’s a pressure regulating system or a variable speed system, your well water pressure will be better than ever. Prior to adjusting the switch, follow safety precautions and look for any faults in the switch components. 5-inch to 24-inch well and pump systems. The most likely cause of a pump not shutting off is the pressure switch. 4. If there’s no pressure, the well pump, well, pressure tank, or switch may require servicing. 2. A pressure switch is the mechanism that will turn on and turn off the well pump based on the Jan 07, 2016 · Pressure switch failure is one common cause of loss of water and other well problems, like a loss of pressure. If there’s no change in the signal, you can determine that the transducer is not responding to pressure. Sensor switch. Whether you have a bedrock or shallow well, water is drawn from within the earth to your house by a water pump. They often get out of whack. 5 Pressure switches. Pressure switches are usually set for 30-50 PSI. This article describes how a water pump pressure control switch works and how to diagnose problems with the building water supply that seem to be traced to the pump control, switch, or to other underlying issues with a water pump, well, piping or other controls. One is the 2 wire pressure switch, and another is a 3-wire pressure switch. There is an electronic switch that we will get into later. Manually closing the pressure control switch should turn the pump on. Irregular, fluctuating water pressure: If you open the faucet and the water is first a cascade, then a trickle, then a cascade again, then you have irregular water pressure. A wires pair also exits and enter the switch. Cable feed from left and out to controller box. Jan 11, 2019 · The pressure switch senses when the water pressure has dropped so it knows when the tank needs more water. The most common problems seen in the switch are corrosive to the wire Jul 16, 2012 · The electrical switch at the pressure tank (grey box) is a fairly common cause of failure in the pump/private well water system; so check the switch to make sure it is working. The switch should be around 3 x 2 inches, and links to a metal tubing placed up to the primary water line. The water just cuts off completely, then comes back on at full pressure. For instance, when the pressure drops below 40 psi, the switch will trigger the well pump to turn on and pump more water into the well tank. Feb 18, 2019 · The tank works by using air pressure and a pressure switch to control your well pump. Your well pump moves water to the water pressure tank. Reduce the pressure setting, and if the pump shuts off you’ve located the problem. The first step in testing the proper operation of the air pressure switch is to check if the switch contacts are opened or closed. The multimeter will show 0 or close to 0 which indicates no resistance. Next is to look for the pressure switch. com to answer any questions or schedule a consultation. Aug 28, 2017 · If you find your well pump still isn’t working after this switch, it’s time to call your local plumber to analyze the well pump system. Keep these tips and steps in mind the next time you need to make an adjustment on a pressure switch. It is not, the timer just opens valves then the pressure switch turns the pump on. Nov 24, 2010 · The Pump Won’t Start. It will only take the removal of a very small amount of water to remove all the pressure from the water system. I accidently broke off the zerk that connects the 1/4" hose to the bottom of the pressure switch. Sep 05, 2017 · A1 Well Drilling & Pump Service has the experience and skills necessary to equip your home with a quality constant pressure system. Check switch adjustments. Your plumber can inspect the system to ensure proper and safe operation. Check the pressure switch using a pressure gauge. Follow (this link) to see the step by step process of how this unassuming tank and pressure switch are the “brains” of your entire water operation! Inside this tank is a rubber bladder that keeps the water and air separate from each other. A pressure switch is the mechanism that will turn on and turn off the well pump based on the There are also problems that may appear to be related to the pressure switch but are actually not. And after checking out some pressure switch connection diagrams, we can say that the 220v well pump wiring switch primarily uses the 2-wire submersible pump. To lower any pressure, turn the nut counter-clockwise . Nov 13, 2018 · Some water systems use a pressure transducer, and these are just as susceptible to freezing as a pressure switch. Drain water from tank to check tank air charge. Well Pressure Switch Replacement Servicing. The pressure switch is near the bottom of the tank. This switch is designed to make sure that the pressure stays at a consistent level so that the AC can function correctly. Low water level in well: Pump may exceed well capacity. There is a high side pressure switch, and low side pressure switch, and they both serve to monitor the system for pressure faults that can damage the compressor. Add air if the pressure is more than 2 psi below the pump cut-in pressure (lowest pressure in the range). The pressure of the AC system fluctuates depending on several factors, such as the ambient temperature, age, and the amount of refrigerant in the system. If the well pump runs constantly, a line may be broken in the system. Aug 25, 2020 · Well pump pressure switch troubleshooting may help you get to the bottom of the issue and restore water flow to your tap. Homeowners can begin troubleshooting at the well pump power switch. Jul 05, 2017 · Sump pump switches are the main link for controlling the sump pump. Second, check the overload protection by checking the circuit breakers and third, check if the pressure switch is damaged. Along with new pressure tank, water softner system. Check to see if there’s power flowing to the system. Signs of Ant Infestation Problems in Your Well. Shut off pump, wait for well to recover. -Check/clean contact points -Tighten all screws Aug 25, 2020 · Call us at (855) 982-2028 or request an appointment for an estimate online for your pressure switch replacement or well system repair. Often, these issues have simple fixes that will restore your water supply. The actual switch is a set of points that look like two sets of points in an old car. 3 LED flashes. This is done by switching off disconnect box to water/pumping system or by a breaker located in the electrical service box marked pump/water system. That brings us to the pressure switch. Drain the tank by opening the closest faucet. Test the air fill valve with an air pressure gauge and see where your pressure lies. Adjusting the Square D well pressure switch increases the water pressure through the entire house. Pressure Pump, Pressure Switch Repair: Introduction I have a number of rain water tanks which I use to water my vegetable garden during the summer. Pressure transducers are typically a small cylinder about 3/4” to 1” in diamter with 1/4” pipe threads on one end that are threaded into your main pipe and a wire that goes to the pump controller. Jan 06, 2016 · When the pressure returns to normal, the cycling switch will close. Pressure switches could also stick sometimes, so it could possibly come on 1 or 3 PSI different from one cycle to the next. But, if the reading is higher then the pressure switch is busted up. Read on to find out some common symptoms that you have to watch out for: Leaking Pressure Switch; Sometimes you will hear complaints that there is compressed air seeping from the pressure switch all the time. Check tank sizing, (Replace tank). The tank becomes refilled to max capacity, and then gets measured by a pressure gauge, which then determines if it shuts off or not. Water pressure control switch repair: Pumptrol switch repair & repair kits. Well Pressure Switch | Well Pressure Tanks | Well Pump Switch Well Pressure Tanks are an important part of a Water Well System to function properly and efficiently. Once the water is flowing from your tap again, you may realize it's the perfect time to upgrade your shower. The most common use for this switch is as well pump run-dry protection. Jul 26, 2006 · You said the well was controlled by the sprinkler timer. Using a non-contact voltage tester, make sure no power is reaching the pressure tank. Jan 06, 2016 · It monitors the pressure of the refrigerant on its respective side of the system. I have a well that feeds a pressure tank in my basement. It is a round-shaped switch that is fairly easy to identify once you have removed your furnace's front cover. If the breaker is tripped then the well pumps is bad or the wire shorted to ground. There could be mineral build up in the the piping that can cause a gauge and pressure switch to do funny things. Ambient pressure can also raise the pre-charge in the tank. When the tank pushes the water in a certain volume, it triggers the pressure switch, which tells the pump to sen more water. It should read at least 20 psi. This is the worst thing you can do to a motor. We are well versed with all kinds of pumps and the issues they are susceptible to. Well Water Pump. 3. 2 mm (0. With the power OFF, take the lid off to do a visual inspection. Aug 17, 2016 · Check the pressure gauge. 008") nozzle are supplied with an integrated vent limiter, see page 8 (Vent limiter). We have a well, new pump installed within the last 2 yrs. Pressure Transducer Troubleshooting in the Field. To remedy this, you will need to either lower your pump or deepen your well. Choose an interior location, away from sunlight and not in a damp place, such as a well pit. Pressure Switch. To check the pressure switch, remove the cover and bang a screwdriver handle against the tube below the switch. The cause for many of these problems can be located and possibly solved without the need for a professional, but in some instances, you may want or need to contact a groundwater The well is reportedly 350 feet deep, Franklin pump control rated for 1hp Square D pressure switch Champion bladder tank about the size of a 30 gallon water heater One inch cast iron Inlet from the pump. We are a licensed and reliable, well pump pressure switch testing plumbing service provider. Generally, they are a normally open switch that closes with either a rise or fall in the pressure it is monitoring, They are used mostly as a safety device but are also used for operation control, such as fan cycle controls for low ambient cooling, starting and stopping for steam boilers, and the list goes on. If you have the common drilled well with an immersion pump in the well and some equipment in the basement, the first thing you should do is go downstairs and take a look. Since your tank is waterlogged and probably needs replacing, your pump motor is cycling. Apr 09, 2018 · Water Pump Pressure Switch Troubleshooting. Turn faucet on until the pressure gauge reads 0 and the water stops. Your determined amount of pressure is 2lbs less the cut in pressure(ex:40-60 switch would require 38psi with tank empty) Turn off power. Just like any other mechanical component, it is bound to wear out, and will therefore need to be replaced from time to time. To raise onlythe cut-off pressure , turn nut #2 clockwise. Here we are using two-wire, plus ground. A pressure switch is the mechanism that will turn on and turn off the well pump based on the Turn off the circuit dedicated to the well pump. This procedure is detailed in the installation manual and should be performed during every installation, as individual system pressures and tank pre-charge can vary. Once the transducer is powered, the 4-20 mA flows from the transducer's - terminal that that is then connected to the + lead of a digital milliamp Here are five relatively common problems to check: Pressure control switch. A pressure switch is an air-electric signal changer. A pressure switch is the mechanism that will turn on and turn off the well pump based on the Step 2: how to tell if pressure switch is bad on well. Pressure switch: Check switch for welded contacts. Jan 09, 2020 · Wiring Diagram for Well Pump Pressure Switch– wiring diagram is a simplified suitable pictorial representation of an electrical circuit. Chris from Rocky Mountain Four Wheel Campers will show you how to adjust the pressure switch on a SHURflo water pump. If you do need to clean out the switch, make sure all power going to the switch is turned off. Dec 16, 2016 · Homeowners will notice a decline in their water pressure until pretty soon, there is no water at all. Dec 10, 2019 · Here are a couple things to check: Double-check that power is running to your well and that there isn’t a short. You have to replace or repair the air compressor pressure switch. Pressure switch repairs. If that starts the pump, then the problem is with the pressure Jan 19, 2018 · Potential Problems With Your Well Pump. . This is placed in the well casing and it pushes the water from below ground into your pressure tank. Check static and drawdown level from well head. A pressure switch is a type of switch that creates an electrical circuit when a certain set pressure has been obtained. Adjusting pressure switch setting will cause higher shut off pressure, increasing the potential for leaks and pump wear. Check tank pressure by placing a tire gauge on the air-charging valve on top of the tank. Don’t suffer from jerky A: With the pump off and the tank empty of water, the compressed air pre-charge should be adjusted to 2 psi below the pressures switch cut-in pressure. Start by checking that the well switch located near your pressure tank hasn't been switched off. They seem like a rather simple piece of equipment but if they're not correctly installed your entire plumbing system could be damaged. Handyman. Confirm that electrical power is available and that circuit breakers (or fuses) are operational. for FREE estimates. The cause of the low water pressure dictates the type of well repair needed to solve the problem. The first could be that power is not being supplied to the pump. This caused problems since the excessive pressure caused some faucets to start leaking. Check the flue for blockages and look for loose wiring. troubleshooting a well pressure switch

3gs cop emj ejx hig 5yv o2m wh8 rsr e6s 4lu rwf jxq q4y 2nv xmx wzk 51w k2s vi0

-->